バイオエンジニアリングおよびバイオエレクトロニクスのジャーナル オープンアクセス

抽象的な

Stem Cell Research & Therapy 2018: Advanced synchrotron radiation tomography in regenerative medicine: A 3D exploration into the intimate interactions between tissues, cells and biomaterials: Alessandra Giuliani- Polytechnic University of Marche, Italy

Alessandra Giuliani

The evaluation of engineered tissues is usually performed by light microscopy on one or more histological sections. This conventional analysis provides only bi-dimensional (2D) information with the consequent risk that the selected sections do not properly represent the entire biopsies. In recent years there has been an increasing interest in a novel approach to evaluate different engineered tissues by means of synchrotron micro-tomography (SCT). Using SCT, tissue regeneration subsequent to grafting hosting sites with different types of biomaterials (with or without stem cells seeding) was recently explored. SCT was shown to be fundamental to explore the dynamic and spatial distribution of regenerative phenomena, also in complex anatomic structures. Traditionally, absorption imaging with SCT is conducted with almost no distance between sample and detector. Homogeneous materials with a low attenuation coefficient (like collagen, unmineralized extracellular matrix, vessels, nerves, etc.) or heterogeneous materials with a narrow range of attenuation coefficients (like the case of heterologous bone scaffolds or graded mineralized bone) produce insufficient contrast for absorption imaging. For such materials, the imaging quality can be enhanced through the use of phase contrast tomography (PCT), often achieved with an increased distance between sample and detector (propagation-based imaging). In the present lecture, the most recent breakthroughs in regenerative medicine will be shown, demonstrating the unique capabilities of the SCT in offering not only an advanced characterization of different biomaterials (to understand the mechanism of their biological behavior as tissue substitute) but also to investigate the growth kinetics of regenerated tissues in different environments.

Since the innovation of Computed Tomography (CT), numerous mechanical advances developed to improve the picture affectability and goals. In any case, no new source types were created for clinical use. In this investigation, just because, reasonable monochromatic X-beams from a synchrotron radiation source were utilized to obtain 3D CTs on patients. The point of this work was to assess the clinical capability of the pictures procured utilizing Synchrotron Radiation CT (SRCT). SRCTs were gained utilizing monochromatic X-beams tuned at 80 keV (0.350 × 0.350 × 2 mm3 voxel size). A quantitative picture quality correlation study was done on apparitions between a cutting edge clinical CT and SRCT pictures. Devoted iterative calculations were created to advance the picture quality and further decrease the conveyed portion by a factor of 12 while keeping a superior picture quality than the one got with a clinical CT scanner. We at long last show in this paper the absolute first SRCT consequences of one patient who got Synchrotron Radiotherapy in a continuous clinical preliminary. This shows the capability of the procedure regarding picture quality improvement at a decreased radiation portion for internal ear representation. Synchrotron radiation small scale tomography (SRµT) is a non-dangerous three-dimensional (3D) imaging procedure that offers high transition for quick information procurement times with high spatial goals. In the hardware business there is not kidding enthusiasm for performing disappointment investigation on 3D microelectronic bundles, numerous which contain different degrees of high-thickness interconnections. Regularly in tomography there is an exchange off between picture goals and the volume of an example that can be imaged. This converse relationship restricts the convenience of customary registered tomography (CT) frameworks since a microelectronic bundle is frequently enormous in cross sectional territory 100-3,600 mm2, however has significant highlights on the micron scale. The miniaturized scale tomography beamline at the Advanced Light Source (ALS), in Berkeley, CA USA, has an arrangement which is versatile and can be customized to an example's properties, i.e., thickness, thickness, and so on., with a most extreme admissible cross-area of 36 x 36 mm. This arrangement likewise has the alternative of being either monochromatic in the vitality extend ~7-43 keV or working with most extreme motion in white light mode utilizing a polychromatic shaft. Introduced here are subtleties of the trial steps taken to picture a whole 16 x 16 mm framework inside a bundle, so as to get 3D pictures of the framework with a spatial goals of 8.7 µm all inside a sweep time of under 3 min. Likewise demonstrated are results from bundles examined in various directions and a separated bundle for higher goals imaging. Interestingly a customary CT framework would take hours to record information with conceivably less fortunate goals. Undoubtedly, the proportion of field-of-view to throughput time is a lot higher when utilizing the synchrotron radiation tomography arrangement. The depiction underneath of the trial arrangement can be actualized and adjusted for use with numerous other multi-materials.

 

X-beam registered tomography (CT) is a broadly utilized strategy for getting cross sectional perspectives on objects. The high power, normal collimation, monochromaticity and vitality tunability of synchrotron X-beam sources might be utilized to give CT pictures of improved quality. The benefits of these frameworks would be that pictures could be created all the more quickly with better spatial goals and diminished shaft antiques. What's more pictures, sometimes, could be gained with basic affectability. As a showing of the ability of such a framework, CT pictures were gotten of four cuts of an extracted pig heart, in which the courses and cardiovascular chambers were loaded up with an iodinated medium. Pictures were taken with occurrence X-beams tuned progressively to energies simply above and beneath the iodine K edge. Iodine explicit pictures were gotten by logarithmically taking away the low vitality picture information from the high vitality information and afterward recreating the picture. CT imaging utilizing synchrotron radiation may turn into a helpful and non-damaging strategy for imaging tests hard to concentrate by different strategies.

免責事項: この要約は人工知能ツールを使用して翻訳されており、まだレビューまたは確認されていません